Orbitrap™ IQ-X™ Tribrid™ 质谱仪
通过结合易用与智能采集方法的智能质谱法,实现更高的数据确定性,从而让您安心地了解未知化合物。
森德仪器提供 赛默飞/Thermo Fisher Orbitrap™ IQ-X™ Tribrid™ 质谱仪 在全国范围内的代理经销、选型咨询、报价沟通、采购支持、安装培训和售后协同服务,价格面议。

微信扫码沟通
扫码添加技术顾问,发送产品型号或应用需求。

Thermo Scientific™ Orbitrap™ IQ-X™ Tribrid™ 质谱仪旨在揭示复杂化学结构,同时为未知化合物的鉴定和小分子分析提供极高程度的多功能性和全面的工作流程支持,让您能够收集更有意义的数据。将行业领先的质谱仪分析技术与智能采集、直观软件以及无需手动操作的远程校准相结合,助您以更大的信心完成结构解析,快速鉴定小分子,从而轻松揭示更多化学结构。
The Orbitrap IQ-X Tribrid MS seamlessly integrates with industry-leading solutions to provide a complete workflow solution, including Thermo Scientific™ Vanquish™ Duo UHPLC Systems, Thermo Scientific™ FAIMS Pro Duo interface for differential ion mobility, Thermo Scientific™ Compound Discoverer™ data analysis software, and the most comprehensive spectral libraries available on Thermo Scientific™ mzCloud™, enabling an intelligent MSn data acquisition strategy to easily conduct small molecule structural elucidation, identification, and characterization.
Other benefits of this mass spectrometry system include:
采购问答
<p>Speed is impacted by the cleanliness and complexity of your samples as well as the processing speed of the computer.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>AcquireX only works for LC experiments because the algorithm specifically looks for things that elute as peaks.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>No, AcquireX is specifically used for small molecule (ions with a charge state of 2 or less) applications.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>AcquireX is available on the Thermo Scientific Orbitrap Fusion Lumos, Orbitrap Fusion, and Orbitrap ID-X Tribrid MS instruments. In regards to the first two instruments, you will need to upgrade to Instrument Control Software Version 3.1 and XCalibur Version 4.2.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
Sende Lab
当前页面用于确认具体仪器型号、参数和采购沟通;如果要从行业热点、测试标准、实验室建设和验收资料角度规划整套能力,可继续查看 Sende Lab。
请填写必填信息,我们将在工作日尽快回复。
<p>Watch this <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center/liquid-chromatography-mass-spectrometry-instruments-support/orbitrap-id-x-tribrid-mass-spectrometer-support/orbitrap-id-x-tribrid-mass-spectrometer-support-getting-started.html?open=g8#g8">video</a>.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>To achieve in-depth MS<sup>n</sup> analysis, this method exhaustively interrogates a precursor using a combination of fragmentation mechanisms, MS<sup>n</sup> levels, and m/z analyzers. At high MS<sup>n</sup> levels, the product ion signals can become quite weak. To address this concern, we developed an “MS<sup>n</sup> Quality Trigger”, which enables the user to trigger complementary ITMS<sup>n</sup> scans if the corresponding FTMS<sup>n</sup> scan S/N drops too low. Mass Frontier 8.0 software can curate “MS<sup>n</sup> library” data into MS<sup>n</sup> “tree” libraries, and the software can search unknown MS<sup>n</sup> data against this local library.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>The assisted collision energy acquisition strategy uses a series of hidden ion trap scans to determine the optimal CE to use in the subsequent analytical scan. These IT spectra only scan a small mass range around the precursor ion (2 Th) to increase the analysis speed. The TIC of these IT scans is compared to the TIC of an IT scan of 0 collision energy to produce a pseudo-breakdown curve of the precursor. Once the amount of unreacted precursor crosses a user-defined threshold (e.g., 20%), the analytical MS/MS scan uses that 'optimal' collision energy. View images and learn more <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center/liquid-chromatography-mass-spectrometry-instruments-support/orbitrap-id-x-tribrid-mass-spectrometer-support/orbitrap-id-x-tribrid-mass-spectrometer-support-getting-started.html?open=g6#g6">here</a>.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>Assisted collision energy is now an available feature on all Tribrid instruments, software version 3.1. Through the Method Editor GUI, users can select different 'Collision Energy Modes' for both HCD and CID activation types in the 'Scan Properties' panel. View images and learn more <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center/liquid-chromatography-mass-spectrometry-instruments-support/orbitrap-id-x-tribrid-mass-spectrometer-support/orbitrap-id-x-tribrid-mass-spectrometer-support-getting-started.html?open=g5#g5">here</a>.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>Internal calibrant (reference) ions are used for real-time fine adjustment of the instrument's mass-to-charge ratio calibration, enabling a correction for otherwise uncompensated errors that are due to temperature changes scan-to-scan. The purpose of the internal calibration is to ensure high mass measurement accuracy, regardless of the MS<sup>n</sup> level. This is especially important for low m/z ions over extended periods of time.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>
<p>The three modes offered are:<br/><br/> 'Background exclusion workflow'<br/> The background exclusion workflow allows users to generate DDMS<sup>n</sup> data with automatic application of instrument generated background exclusion list. This allows detection of low level analytes in the presence of a complex background.<br/><br/> 'Background exclusion and component inclusion workflow'<br/> The background exclusion and component inclusion workflow allows DDMS<sup>n</sup> data generation with automatic application of instrument generated inclusion and exclusion list. Multiple samples can be submitted in one sequence for their respective inclusion and exclusion list generation followed by one identification experiment using those lists.<br/><br/> 'Deep scan workflow' <br/> The deep scan workflow allows the generation of DDMS<sup>n</sup> data with automatic application of inclusion and exclusion lists followed by automated re-injection of the sample. The inclusion and exclusion lists are updated prior to re-injection by moving triggered targets from the inclusion list to the exclusion list allowing deeper interrogation of complex samples.<br/><br/>Find additional tips, troubleshooting help, and resources within our <a href="https://www.thermofisher.com/us/en/home/technical-resources/technical-reference-library/mass-spectrometry-support-center.html?icid=faqsc39">Mass Spectrometry Support Center</a>.</p>